The concurrent validity and reliability of the Leg Motion system
4.6 (757) In stock
Background New reliable devices for range of motion (ROM) measures in older adults are necessary to improve knowledge about the functional capability in this population. Dorsiflexion ROM limitation is associated with ankle injuries, foot pain, lower limb disorders, loss of balance, gait control disorders and fall risk in older adults. The aim of the present study was to assess the validity and reliability of the Leg Motion device for measuring ankle dorsiflexion ROM in older adults. Methods Adescriptive repeated-measures study was designed to test the reliability of Leg Motion in thirty-three healthy elderly patients older than 65 years. The subjects had to meet the following inclusion and exclusion criteria in their medical records: older than 65 years; no lower extremity injury for at least one year prior to evaluation (meniscopathy, or fractures) and any chronic injuries (e.g., osteoarthritis); no previous hip, knee or ankle surgery; no neuropathic alterations and no cognitive conditions (e.g., Alzheimer’s disease or dementia). Participants were recruited through the person responsible for the physiotherapist area from a nursing center. The subjects were evaluated in two different sessions at the same time of day, and there was a break of two weeks between sessions. To test the validity of the Leg Motion system, the participants were measured in a weight-bearing lunge position using a classic goniometer with 1° increments, a smartphone with an inclinometer standard app (iPhone 5S®) with 1° increments and a measuring tape that could measure 0.1 cm. All testing was performed while the patients were barefoot. The researcher had ten years of experience as a physiotherapist using goniometer, tape measure and inclinometer devices. Results Mean values and standard deviations were as follows: Leg Motion (right 5.15 ± 3.08; left 5.19 ± 2.98), tape measure (right 5.12 ± 3.08; left 5.12 ± 2.80), goniometer (right 45.87° ± 4.98; left 44.50° ± 5.54) and inclinometer app (right 46.53° ± 4.79; left 45.27° ± 5.19). The paired t-test showed no significant differences between the limbs or between the test and re-test values. The test re-test reliability results for Leg Motion were as follows: the standard error of the measurement ranged from 0.29 to 0.43 cm, the minimal detectable difference ranged from 0.79 to 1.19 cm, and the intraclass correlation coefficients (ICC) values ranged from 0.97 to 0.98. Conclusions The results of the present study indicated that the Leg Motion device is a valid, reliable, accessible and portable tool as an alternative to the classic weight-bearing lunge test for measuring ankle dorsiflexion ROM in older adults.
Reliability and validity of OpenPose for measuring hip-knee-ankle angle in patients with knee osteoarthritis
Sensors, Free Full-Text
PDF) The concurrent validity and reliability of the Leg Motion system for measuring ankle dorsiflexion range of motion in older adults
The Concurrent Validity and Reliability of Single Leg Squat Among Physically Active Females with and without Dynamic Knee Valgus
PDF) Concurrent Validity and Test-retest Reliability of the OPTOGait Photoelectric Cell System for the Assessment of Spatio-temporal Parameters of the Gait of Young Adults
PDF) Assessments of Lumbar Flexion Range of Motion
PDF) The concurrent validity and reliability of the Leg Motion system for measuring ankle dorsiflexion range of motion in older adults
PDF) Validity and Reliability of an Inertial Device for Measuring Dynamic Weight-Bearing Ankle Dorsiflexion
Sensors, Free Full-Text
Concurrent validity (compared with force platform) of the AS.
Measurement of Knee Joint Range of Motion With A Digital Goniometer: A Reliability Study, PDF, Physical Therapy
Test-retest reliability of ankle range of motion, proprioception, and balance for symptom and gender effects in individuals with chronic ankle instability - ScienceDirect
Falls rate increase and foot dorsal flexion limitations are exhibited in patients who suffer from asthma: A novel case-control study
Sensors, Free Full-Text
PDF) Concurrent validity of lower extremity kinematics and jump characteristics captured in pre-school children by a markerless 3D motion capture system
Ankle Dorsiflexion Limitation and Flat Feet
5 Essential Exercises That Improve Ankle Mobility
- CW-X Endurance Generator Tights (Black) Women's Workout The athletic and supportive CW-X Endurance Generator Tight…
- 29 Black Female Fitness Models On Instagram - That Sister
- Plain-coloured crew-neck sweatshirt
- Let's Get to Work Athletic Skort in Green
- The best running gear for women 2023: from M&S to Nike, adidas
- Dfyne leggings - Gem